Difference between revisions of "Slotcar Platooning Communication"

From DCEwiki
Jump to: navigation, search
m (Random ideas)
m (Notes)
Line 6: Line 6:
 
* Use trigger in Normal mode, set it to descreasing edge of MRDY signal, timescale 50 us and y scale 1V, trigger to 1.5V. After using reset sequence, the data comes after cca 780-800 ms.
 
* Use trigger in Normal mode, set it to descreasing edge of MRDY signal, timescale 50 us and y scale 1V, trigger to 1.5V. After using reset sequence, the data comes after cca 780-800 ms.
 
=== Notes ===
 
=== Notes ===
After reset sequence to measure the first initial communication on the oscilloscope, wait for cca 500 ms. The first drop in SRDY is just a disturbance, not the indication to be ready to receive data.
+
*After reset sequence to measure the first initial communication on the oscilloscope, wait for cca 500 ms. The first drop in SRDY is just a disturbance, not the indication to be ready to receive data.
  
B1 USER: User and Wake-Up button connected to the I/O PA0. On SmartRF05 Evalution Board: P10-19.
+
*B1 USER: User and Wake-Up button connected to the I/O PA0. On SmartRF05 Evalution Board: P10-19.
 +
 
 +
* LD7 detects MRDY position: if MRDY is low - LD7 is on, if MRDY is high - LD7 is off.
  
 
== Random ideas ==
 
== Random ideas ==

Revision as of 10:05, 16 May 2014

General description

The goal of this project is to provide communication between PC and vehicular platoons using specifications of Zigbee network stack as a base.

Oscilloscope settings

  • Use trigger in Normal mode, set it to descreasing edge of MRDY signal, timescale 50 us and y scale 1V, trigger to 1.5V. After using reset sequence, the data comes after cca 780-800 ms.

Notes

  • After reset sequence to measure the first initial communication on the oscilloscope, wait for cca 500 ms. The first drop in SRDY is just a disturbance, not the indication to be ready to receive data.
  • B1 USER: User and Wake-Up button connected to the I/O PA0. On SmartRF05 Evalution Board: P10-19.
  • LD7 detects MRDY position: if MRDY is low - LD7 is on, if MRDY is high - LD7 is off.

Random ideas

  • There are several ways for applying power to the SmartRF05. The power source can be selected using the power source selection jumper on header P11 (1-2 for battery, 2-3 for USB). SRDY signal doesnt change according to expectaion if USB was selected as power source.

Back to slotcar platooning